Global Water
800-876-1172 globalw.com
- 1 -
FL16 Flow Logger
Covers USB (FL16U) and Serial (FL16S) Versions
Global Water
Instrumentation, Inc.
11390 Amalgam Way
Gold River, CA 95670
T: 800-876-1172
Int’l: (916) 638-3429, F: (916) 638-3270
11/30/09
01-497
Vista de página 0
1 2 3 4 5 6 ... 36 37

Resumo do Conteúdo

Página 1 - Global Water

Global Water 800-876-1172 • globalw.com - 1 - FL16 Flow Logger Covers USB (FL16U) and Serial (FL16S) Versions Global Water Instrumentation,

Página 2 - ▫ ▫ ▫ 4

Global Water 800-876-1172 • globalw.com - 10 - 6) Two drivers are sometimes required so the Hardware Wizard repeats the exact same process again.

Página 3

Global Water 800-876-1172 • globalw.com - 11 - IX. Direct Connection: Important: This data logger supports an Auto Baud Rate Mode which automat

Página 4

Global Water 800-876-1172 • globalw.com - 12 - Serial connection (FL16S) is generally done using the serial cable provided with the logger through

Página 5

Global Water 800-876-1172 • globalw.com - 13 - Use initialization file Select the modem’s COM port Sample initial

Página 6

Global Water 800-876-1172 • globalw.com - 14 - Once a connection is established, “Connect” will appear for a few seconds along with the baud rate

Página 7

Global Water 800-876-1172 • globalw.com - 15 - XI. Main Screen: The main screen is where the status and option menus are accessed. The FL16 da

Página 8

Global Water 800-876-1172 • globalw.com - 16 - Tool Bar: The tool bar at the top of the screen has 3 options; File, Action and Help. In this scr

Página 9

Global Water 800-876-1172 • globalw.com - 17 - Records: This field indicates the number of data recordings in memory. Logging State: This shows

Página 10

Global Water 800-876-1172 • globalw.com - 18 - Bar Graphs: The bar graphs show a visual representation of the most recent data reading taken by

Página 11

Global Water 800-876-1172 • globalw.com - 19 - XII. On-Line Help Files: Clicking on Help displays the on-line help files which contain all of

Página 12

Global Water 800-876-1172 • globalw.com - 2 - Congratulations on your purchase of a Global FL16 Flow Logger. This instrument has been quality tes

Página 13 - Connect 19200

Global Water 800-876-1172 • globalw.com - 20 - XIII. Get History: Clicking the Get History button begins the downloading of the historical data i

Página 14

Global Water 800-876-1172 • globalw.com - 21 - Save to File: Clicking this button allows the data to be exported to an Excel compatible .CSV f

Página 15

Global Water 800-876-1172 • globalw.com - 22 - Action: The Action menu has two options, “Program Settings” and “Initialize to Default Values”.

Página 16

Global Water 800-876-1172 • globalw.com - 23 - Sensor Warm-up Time: To conserve battery life, the sensors do not normally have power applied to

Página 17

Global Water 800-876-1172 • globalw.com - 24 - Log Upon Deviation: Clicking the “Log only if Channel 1 change exceeds +/-“ box causes the log

Página 18

Global Water 800-876-1172 • globalw.com - 25 - XVI. Analog Setup: The Analog Setup screen sets the engineering units and calibration numbers for

Página 19

Global Water 800-876-1172 • globalw.com - 26 - Enable: If the “Enable” box at the top of a column is checked, data for that channel will be show

Página 20

Global Water 800-876-1172 • globalw.com - 27 - Decimal Places: From the pull-down menu, select the number of decimal places to the right of the d

Página 21

Global Water 800-876-1172 • globalw.com - 28 - XVII. Flow Calculation Setup: The Flow Calculation menu is where the flow parameters are set

Página 22

Global Water 800-876-1172 • globalw.com - 29 - separate bar graphs and are both stored; along with the level, temperature and battery voltage data

Página 23

Global Water 800-876-1172 • globalw.com - 3 - I. Checklist: a. FL16S (Serial) or FL16U (USB) Data Logger b. FL16 Sewer Flow Level Sensor c.

Página 24

Global Water 800-876-1172 • globalw.com - 30 - Table File Mode: This powerful feature allows you to load a user defined tables for correlating le

Página 25

Global Water 800-876-1172 • globalw.com - 31 - Level Offset: This setting lets you add or subtract a specified amount to or from the measured wate

Página 26

Global Water 800-876-1172 • globalw.com - 32 - XVIII. Programming Program Settings: The Program Settings button at the bottom of the setup men

Página 27

Global Water 800-876-1172 • globalw.com - 33 - XIX. Calculations: Manning’s equation: Velocity = (1.486 / n) * (WA / WP) ^ 0.6667 * (Slope) ^ 0

Página 28

Global Water 800-876-1172 • globalw.com - 34 - XX. Modem Cable Diagram (FL16S Only): The following wiring diagram is used to make a cable to con

Página 29

Global Water 800-876-1172 • globalw.com - 35 - XXI. Maintenance: a. Except for battery and desiccant, there are no user-serviceable parts

Página 30

Global Water 800-876-1172 • globalw.com - 36 - XXIII. Customer Support: Call Global Water for tech support: 800-876-1172 or 916-638-3429 (many

Página 31

Global Water 800-876-1172 • globalw.com - 37 - Declaration of CE Conformity Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA

Página 32

Global Water 800-876-1172 • globalw.com - 4 - IV. FL16 Specifications: Logger: Power Supply: Two 9VDC Lithium batteries standard 8 VDC Min.

Página 33

Global Water 800-876-1172 • globalw.com - 5 - Level Sensor: Sensor Element: Silicone Diaphragm, Wet/Wet Transducer Range: Level: 0-3 feet

Página 34

Global Water 800-876-1172 • globalw.com - 6 - V. Introduction The FL16 Flow Monitor uses Global Water’s standard WL6 Level Logger with a redes

Página 35

Global Water 800-876-1172 • globalw.com - 7 - VI. Software Compatibility Global Water offers various software packages which are compatible with

Página 36

Global Water 800-876-1172 • globalw.com - 8 - VIII. Software Installation: Global Logger Installation: This software is for use on Windows based

Página 37 - Declaration of CE Conformity

Global Water 800-876-1172 • globalw.com - 9 - Click Next. 2) Do not let Windows automatically install the software. Click “Install from a speci