Xylem COND3210 HANDHELD CONDUCTIVITY METERS Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Ferramentas Xylem COND3210 HANDHELD CONDUCTIVITY METERS. Xylem COND3210 HANDHELD CONDUCTIVITY METERS User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Cond 3210

ba75794e01 01/2009Cond 3210Operating manualConductivity meterHOLDAR25.01417°C15.11.200808:37ӕµS/cmMenu[Tr25][nLF][ 0.835 1/cm]

Página 2 - © Weilheim 2009, WTW GmbH

Safety Cond 321010ba75794e01 01/20092.1 Authorized useAuthorized use of the meter consists exclusively of the measurement of conductivity, resistivity

Página 3 - Cond 3210 - Contents

Cond 3210 Safety11ba75794e01 01/2009Safe operation If safe operation is no longer possible, the meter must be taken out of service and secured against

Página 4 - Contents Cond 3210

Safety Cond 321012ba75794e01 01/2009

Página 5 - 1Overview

Cond 3210 Commissioning13ba75794e01 01/20093 Commissioning3.1 Scope of deliveryz Conductivity meter Cond 3210 z 4 batteries 1.5 V Mignon type AAz Shor

Página 6 - 1.1 Keypad

Commissioning Cond 321014ba75794e01 01/2009NoteAlternatively, you can also use Ni-MH rechargeable batteries (type Mignon AA). In order to charge the b

Página 7 - 1.2 Display

Cond 3210 Operation15ba75794e01 01/20094 Operation4.1 Switching on the meterSwitching on Press the <On/Off> key.The meter performs a self-test.

Página 8 - 1.3 Socket field

Operation Cond 321016ba75794e01 01/20094.2 General operating principlesThis section contains basic information on the operation of the Cond 3210. Oper

Página 9 - 2 Safety

Cond 3210 Operation17ba75794e01 01/20094.2.2 NavigationMeasured value display In the measured value display, you can z Open the respective measuring m

Página 10 - ECHNICAL DATA

Operation Cond 321018ba75794e01 01/2009z FunctionsFunctions are designated by the name of the function. They are immediately carried out by confirming

Página 11 - Cond 3210 Safety

Cond 3210 Operation19ba75794e01 01/20094.2.3 Example 1 on navigation: Setting the language1 Press the <On/Off> key.The measured value display ap

Página 12 - Safety Cond 3210

Cond 3210ba75794e01 01/2009Accuracy whengoing to pressThe use of advanced technology and the high quality standard of our instruments are the result o

Página 13 - 3 Commissioning

Operation Cond 321020ba75794e01 01/20095 Select the General submenu with <▲><▼>. The current selection is displayed with a frame.6 Open th

Página 14 - Commissioning Cond 3210

Cond 3210 Operation21ba75794e01 01/20099 Confirm the setting with <ENTER>. The meter switches to the measuring mode.The selected language is act

Página 15 - 4 Operation

Operation Cond 321022ba75794e01 01/20094.2.4 Example 2 on navigation: Setting the date and timeThe measuring instrument has a clock with a date functi

Página 16 - Operation Cond 3210

Cond 3210 Operation23ba75794e01 01/20094 Change and confirm the setting with <▲><▼> and <ENTER>.The minutes are highlighted.5 Change

Página 17 - Cond 3210 Operation

Operation Cond 321024ba75794e01 01/20094.3 Sensor-independent settingsThe Storage & config menu comprises the following settings:z System (see sec

Página 18

Cond 3210 Operation25ba75794e01 01/20094.3.2 Data storageThis menu contains all functions to display, edit and erase stored measured values and calibr

Página 19

Operation Cond 321026ba75794e01 01/20094.3.3 Automatic Stability controlThe automatic Stability control (AutoRead) function continuously checks the st

Página 20

Cond 3210 Operation27ba75794e01 01/20094.4 Conductivity4.4.1 General informationYou can measure the following variables:z Conductivityz Specific resis

Página 21

Operation Cond 321028ba75794e01 01/20094.4.2 MeasuringYou can carry out conductivity measurements as follows:Selecting thedisplayedmeasured variableYo

Página 22 - 14:53:40

Cond 3210 Operation29ba75794e01 01/2009Stability control(AutoRead )The stability control function (AutoRead) continually checks the stability of the m

Página 23

Cond 3210 Contents3ba75794d01 01/2009Cond 3210 - Contents1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51.1 K

Página 24 - _>[Menu] key in

Operation Cond 321030ba75794e01 01/20094.4.3 Temperature compensationThe calculation of the temperature compensation is based on the preset reference

Página 25

Cond 3210 Operation31ba75794e01 01/20094.4.4 Settings for conductivity measuring cellsOverview The following settings are possible for conductivity me

Página 26

Operation Cond 321032ba75794e01 01/2009Measurement / Measuring cell / TypeMeasuring cell usedCal Measuring cells the cell constant of which is determi

Página 27 - 4.4 Conductivity

Cond 3210 Operation33ba75794e01 01/2009Measurement / Temp. comp. (TC) / Linear coeff.0.000 ... 3.000 %/KCoefficient of the linear temperature compensa

Página 28 - [Tr25][nLF][ 0.835 1/cm]

Operation Cond 321034ba75794e01 01/20094.4.5 Determining the cell constant (calibration in control standard)Why determine the cellconstant?Aging sligh

Página 29 - Δ T (° C): Better than 0.02

Cond 3210 Operation35ba75794e01 01/2009Determining the cellconstantFor this calibration procedure, the Measuring cell setting must be set to cal in th

Página 30

Operation Cond 321036ba75794e01 01/20094.5 Data storageYou can transmit measured values (datasets) to the data storage:z Manual storage (see section 4

Página 31

Cond 3210 Operation37ba75794e01 01/20094.5.1 Manual storageYou can transmit a measurement dataset to the data storage as follows. If the storage is fu

Página 32

Operation Cond 321038ba75794e01 01/20094.5.2 Displaying and editing the measurement data storage The contents of the manual measurement data storage c

Página 33

Cond 3210 Operation39ba75794e01 01/2009following options:z Switch directly to the measured value display with <M>.z Quit the display and move to

Página 34

Contents Cond 32104ba75794d01 01/20094.5.3 Erasing the measurement data storage . . . . . . . 394.6 Reset . . . . . . . . . . . . . . . . . . . . . .

Página 35 - _> key

Operation Cond 321040ba75794e01 01/20094.6 ResetYou can reset (initialize) all sensor settings and sensor-independent settings separately from each ot

Página 36 - 4.5 Data storage

Cond 3210 Operation41ba75794e01 01/20094.6.2 Resetting the system settingsThe following system settings can be reset to the delivery status:The system

Página 37

Operation Cond 321042ba75794e01 01/2009

Página 38 - _>[Menu] key in the

Cond 3210 Maintenance, cleaning, disposal43ba75794e01 01/20095 Maintenance, cleaning, disposal5.1 MaintenanceThe only maintenance activity required is

Página 39

Maintenance, cleaning, disposal Cond 321044ba75794e01 01/20095.2 CleaningOccasionally wipe the outside of the measuring instrument with a damp, lint-f

Página 40 - 4.6 Reset

Cond 3210 What to do if...45ba75794e01 01/20096 What to do if...Error message,OFLError message,ErrorSensor symbol flashesDisplayMeter does not react t

Página 41 - _>[Menu]

What to do if... Cond 321046ba75794e01 01/2009

Página 42

Cond 3210 Technical data47ba75794e01 01/20097 Technical data 7.1 General dataDimensions approx. 180 x 80 x 55 mmWeight approx. 0.4 kgMechanical struct

Página 43 - 5.1 Maintenance

Technical data Cond 321048ba75794e01 01/20097.2 Measuring ranges, resolution, accuracyMeasuring ranges,resolutionParameter Measuring range Resolutionӕ

Página 44 - 5.4 Disposal

Cond 3210 Technical data49ba75794e01 01/2009NoteThe accuracy values specified here apply exclusively to the meter. The accuracy of the measuring cell

Página 45 - _>[Menu] / Storage &

Cond 3210 Overview5ba75794e01 01/20091OverviewThe Cond 3210 compact precision conductivity meter enables you to perform conductivity measurements quic

Página 46 - What to do if... Cond 3210

Technical data Cond 321050ba75794e01 01/2009FCC Class A Equipment StatementNote: This equipment has been tested and found to comply with the limits f

Página 47 - 7 Technical data

Cond 3210 Lists51ba75794e01 01/20098Lists This chapter provides additional information and orientation aids.Specialist terms The glossary briefly expl

Página 48 - (Resistivity)

Lists Cond 321052ba75794e01 01/2009ReferencetemperatureFixed temperature value to compare temperature-dependent measured values. For conductivity meas

Página 49 - Cond 3210 Technical data

Cond 3210 ListsIndex53ba75794d01 01/2009AAuthorized use . . . . . . . . . . . . . . . . . . . . . . 10Automatic switch-off . . . . . . . . . . . . . .

Página 50 - Technical data Cond 3210

Lists Cond 321054ba75794d01 01/2009

Página 52 - Lists Cond 3210

Wissenschaftlich-Technische Werkstätten GmbHDr.-Karl-Slevogt-Straße 1D-82362 WeilheimGermanyTel: +49 (0) 881 183-0+49 (0) 881 183-100Fax: +49 (0) 881

Página 53

Overview Cond 32106ba75794e01 01/20091.1 KeypadIn this operating manual, keys are indicated by brackets <..> . The key symbol (e.g. <ENTER>

Página 54

Cond 3210 Overview7ba75794e01 01/20091.2 DisplayFunction displayindicators<ENTER>: <ENTER_>:Opens the menu for measurement settings / conf

Página 55

Overview Cond 32108ba75794e01 01/20091.3 Socket fieldCautionOnly connect measuring cells to the meter that cannot return any voltages or currents that

Página 56

Cond 3210 Safety9ba75794e01 01/20092 SafetyThis operating manual contains basic instructions that you must follow during the commissioning, operation