4.8 Configuration
You can adapt the handheld meter to your individual requirements. To
do this, the following parameters can be changed (the status on deliv-
ery is marked in bold):
Note
You can leave the configuration menu at any time with <M> . The pa-
rameters that have already been changed are stored.
Baudrate
Baud rate 1200, 2400, 4800, 9600
Air pressure display Current value in mbar
(no input possible)
Calibration
intervals
pH 1 ... 7 ... 999 dInt 3
O
2
1 ... 14 ... 999 dInt 4
: 1 ... 180 ... 999 dInt 5
Date/time Any
1 Switch off the measuring instrument.
2 Press the <M> key and hold it down.
3 Press the <ON/OFF> key.
The display test appears briefly on the display. The measuring
instrument then switches automatically to the setting of the
baud rate.
4 Select the required Baud rate with <> <>.
5 Confirm with <RUN/ENTER>. CAL dISP appears on the dis-
play.
Day.Month No.