Vista de página 0
Global Water
800-876-1172 globalw.com
- 1 -
GL500-2-1 Data Logger
Covers GL500U-2-1 and GL500S-2-1 Data Loggers
Global Water
Instrumentation, Inc.
11390 Amalgam Way
Gold River, CA 95670
T: 800-876-1172
Int’l: (916) 638-3429, F: (916) 638-3270
11/30/09
01-460
Vista de página 0
1 2 3 4 5 6 ... 31 32

Resumo do Conteúdo

Página 1 - GL500-2-1 Data Logger

Global Water 800-876-1172 • globalw.com - 1 - GL500-2-1 Data Logger Covers GL500U-2-1 and GL500S-2-1 Data Loggers Global Water Instrumentati

Página 2 - ▫ ▫ ▫ ▫ 4

Global Water 800-876-1172 • globalw.com - 10 - GL500S Only settings must be made to the remote modem and an initialization file may be required t

Página 3

Global Water 800-876-1172 • globalw.com - 11 - GL500S Only Sample initialization text file: This is for reference and applies to an external US Ro

Página 4

Global Water 800-876-1172 • globalw.com - 12 - IX. Main Screen: The main screen is where the status and option menus are accessed. The data lo

Página 5

Global Water 800-876-1172 • globalw.com - 13 - Tool Bar: The tool bar at the top of the screen has 3 options; File, Action and Help. In this scr

Página 6

Global Water 800-876-1172 • globalw.com - 14 - Records: This field indicates the number of data recordings in memory. Logging State: This shows

Página 7

Global Water 800-876-1172 • globalw.com - 15 - Bar Graphs: The bar graphs show a visual representation of the most recent data reading taken by u

Página 8

Global Water 800-876-1172 • globalw.com - 16 - X. On-Line Help Files: Clicking on Help displays the on-line help files which contain all of th

Página 9

Global Water 800-876-1172 • globalw.com - 17 - XI. Get History: Clicking the Get History button begins the downloading of the historical data in

Página 10

Global Water 800-876-1172 • globalw.com - 18 - Save to File: Clicking this button allows the data to be exported to an Excel compatible .CSV f

Página 11 - Connect 19200

Global Water 800-876-1172 • globalw.com - 19 - Action: The Action menu has two options, “Program Settings” and “Initialize to Default Values”. P

Página 12

Global Water 800-876-1172 • globalw.com - 2 - Congratulations on your purchase of a Global Water GL500-2-1 Data Logger. This instrument has been

Página 13

Global Water 800-876-1172 • globalw.com - 20 - Name: The logger is a user definable name to identify the logger. Up to 32 characters are allowed

Página 14

Global Water 800-876-1172 • globalw.com - 21 - Logarithmic Timing: Typically used in groundwater pump studies, this mode speeds up the sample rat

Página 15

Global Water 800-876-1172 • globalw.com - 22 - Alarm Times: Check the box associated with each alarm to enable that feature and enter the desired

Página 16

Global Water 800-876-1172 • globalw.com - 23 - The calibration of channel one to a water level sensor is discussed in the following example where

Página 17

Global Water 800-876-1172 • globalw.com - 24 - Disp High: This field sets the upper limit of the bar graph displayed in the main screen and provi

Página 18

Global Water 800-876-1172 • globalw.com - 25 - Click on the Low EU field and enter the low engineering unit that will be used to calibrate the

Página 19

Global Water 800-876-1172 • globalw.com - 26 - Enable: Checking the Enable box allows the display of the data for that channel in the historical

Página 20

Global Water 800-876-1172 • globalw.com - 27 - XVI. Programming Program Settings: The Program Settings button at the bottom of the setup menus

Página 21

Global Water 800-876-1172 • globalw.com - 28 - XVII. Input Connections The digital input uses a standard RCA jack on the bottom of the case

Página 22

Global Water 800-876-1172 • globalw.com - 29 - XVIII. Modem Cable Diagram (GL500S Only): The following wiring diagram is used to make a cable t

Página 23

Global Water 800-876-1172 • globalw.com - 3 - I. Checklist: a. GL500U-2-1 (USB) or GL500S-2-1 (Serial) Data Logger b. GL500-2-1 Data Logger M

Página 24

Global Water 800-876-1172 • globalw.com - 30 - XIX. Maintenance: a. Except for battery and desiccant, there are no user-serviceable part

Página 25

Global Water 800-876-1172 • globalw.com - 31 - XXI. Customer Support: Call Global Water for tech support: 800-876-1172 or 916-638-3429 (many pr

Página 26

Global Water 800-876-1172 • globalw.com - 32 - Declaration of CE Conformity Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA

Página 27

Global Water 800-876-1172 • globalw.com - 4 - IV. Specification: Power Supply: Two 9VDC alkaline batteries standard 5 VDC Min. to 24.0 VDC Ab

Página 28

Global Water 800-876-1172 • globalw.com - 5 - V. System Requirements: Desktop or Laptop computer with: 1) Windows 98, ME, 2000, XP Vista or W

Página 29

Global Water 800-876-1172 • globalw.com - 6 - GL500U Only The following menus apply to the Windows XP operating system. 1) Do not let Windows s

Página 30

Global Water 800-876-1172 • globalw.com - 7 - GL500U Only 4) The Hardware Wizard searches for the driver. If Windows advises that the software

Página 31

Global Water 800-876-1172 • globalw.com - 8 - 8) To confirm the installation, look in the Device Manager and find the USB Serial Port. The COM se

Página 32 - Declaration of CE Conformity

Global Water 800-876-1172 • globalw.com - 9 - To make a direct connection to the logger, click the “Direct” option and from the “P