Resumo do Conteúdo

Página 1 - Centrifugal Pumps

Installation, Operation,and Maintenance ManualSeries e-90 Close-Coupled In-LineCentrifugal Pumps

Página 2

Product DescriptionGeneral descriptionThe Series e-90 in-line mounted centrifugal pump is a close-coupled pump.This pump is available for pipe sizes t

Página 3 - Table of Contents

InstallationPreinstallationPrecautionsWARNING:• When installing in a potentially explosive environment, make sure that the motor isproperly certified.•

Página 4 - Introduction and Safety

Mode of dischargeYou can install this pump to discharge either vertically or horizontally. The arrow on thepump body must point in the direction of th

Página 5 - User safety

Check Explanation/comment CheckedCheck that new flange gaskets are installed betweenthe flanges of the pump body suction and dischargepipes. Make sure t

Página 6 - Environmental safety

Commissioning, Startup, Operation,and ShutdownPreparation for startupWARNING:• Failure to follow these precautions before you start the unit will lead

Página 7 - Product warranty

Pump rotation is clockwise when viewed from the back of the motor. An arrow isprovided to show rotational direction.3. Lock out power to the driver.Lu

Página 8 - Transportation and Storage

Pump operation precautionsGeneral considerationsCAUTION:• Vary the capacity with the regulating valve in the discharge line. Never throttle theflow fro

Página 9

MaintenanceDisassemblyDisassembly precautionsThis manual clearly identifies accepted methods for disassembling units. These methodsmust be adhered to.W

Página 10 - Product Description

WARNING:Make certain that the internal pressure is relieved before you continue.Failure to follow these instructions can result in serious personal in

Página 11 - Installation

NOTICE:These seal assemblies consist of a stationary seal insert assembly and a rotating sealassembly. Each of these components must be replaced when

Página 13 - Connect the wiring

4. Clean the motor and impeller threads. Apply Loctite 7471 Primer to the threads of themotor and impeller. Allow to dry. Apply a small amount of Loct

Página 17 - Maintenance

Xylem |’zīləm|1) The tissue in plants that brings water upward from the roots2) A leading global water technology companyWe're 12,000 people unifi

Página 18 - Typical cross section

Table of ContentsIntroduction and Safety...

Página 19 - Reassembly

Introduction and SafetyIntroductionPurpose of this manualThe purpose of this manual is to provide necessary information for:• Installation• Operation•

Página 20 - Dealer servicing

• Personal accidents and health problems• Damage to the product• Product malfunctionHazard levelsHazard level IndicationDANGER: A hazardous situation

Página 21

• Protective gloves• Gas mask• Hearing protection• First-aid kit• Safety devicesNOTICE:Never operate a unit unless safety devices are installed. Also

Página 22

WARNING:Radiation Hazard. Do NOT send the product to Xylem if it has been exposed to anynuclear radiation.Electrical installationFor electrical instal

Página 23

Transportation and StorageInspect the deliveryInspect the package1. Inspect the package for damaged or missing items upon delivery.2. Note any damaged

Página 24 - Xylem

Treat bearing and machined surfaces so that they are well preserved. Refer to the driveunit and coupling manufacturers for their long-term storage pro