Página 1 - Series A-C 8100

G&L PumpsSeries A-C 8100 Base Mounted Centrifugal PumpsINSTRUCTION MANUALAC5659Revision AINSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER’S USE.G

Página 2 - G&L PUMP

13. DOWELINGDowel the pump and driving unit as follows:a. Drill holes through diagonally opposite feet and into thebase. Holes must be of a diameter 1

Página 3 - B. SAFETY INSTRUCTIONS

11Suction piping should be short in length, as direct as possible,and never smaller in diameter than the pump suction opening.If the suction pipe is s

Página 4 - IMPORTANT

1216. Mechanical SealsMechanical seals are preferred over packing on some applica-tions because of better sealing qualities and longer service-ability

Página 5 - General A-C 8100 Instructions

13CHANGING ROTATIONSeries A-C 8100 centrifugal pumps can be operated left hand or right hand when viewed from the pump end of the pump. If you wish t

Página 6 - 1" GAP

14C. TROUBLE SHOOTINGBetween regular maintenance inspections, be alert for signs ofmotor or pump trouble. Common symptoms are listed below. Correct an

Página 7 - REMOVAL/INSTALLATION

15Not Enough PressureCAUSES CURES21. Mechanical defects. See item 14 and 15.22. Obstruction in liquid passages. Dismantle pump and inspect passages of

Página 8 - INCORRECT ALIGNMENT

16MAINTENANCE1. General MaintenanceOperating conditions vary so widely that to recommend oneschedule of preventative maintenance for all centrifugalpu

Página 9

175. Packing SealWhen a pump with packing is first started it is advisable tohave the packing slightly loose without causing an air leak. Asthe pump r

Página 10 - (Piping Supports Not Shown)

1. Mechanical Seals on ShaftDISASSEMBLYNOTICE: Numbers that appear in parenthesis ( ), such as (1-939-9), may be used to order replacement parts. 1.

Página 11

19Remove coupler guard (see separate instructions on pageRemove external tubing (1-939-9) if supplied.2. Loosen but do not remove main joint capscrews

Página 12 - B. OPERATION

2 MODEL NO.SERIALNO.IDENT.NO.G.P.M. FT. HP R.P.M.P.S.I.MAX.WORKPRESS.1500 60 1780PUMPSERIESDUTYPOINTMAXIMUMW

Página 13 - CHANGING ROTATION

ASSEMBLYAll bearings, “O” rings, seals and gaskets should be replacedwith new parts during assembly. All reusable parts should becleaned of all foreig

Página 14 - 3 rated capacity from

11. Slide the deflector over the shaft end; then push the shaftend through the oil seal and slide stuffing box fully ontothe shaft. DO NOT COMPRESS TH

Página 15

222. Mechanical Seals on Shaft SleeveDISASSEMBLYNOTICE: Numbers that appear in parenthesis ( ), such as(1-939-9), may be used to order replacement pa

Página 16

Remove coupler guard (see separate instructions on page29) and disconnect coupler.Remove external tubing (1-939-9) if supplied.2. Loosen but do not re

Página 17 - A-C 8100 Pump

14. Remove the other seal, shaft sleeve and nut as describedin steps 11, 12 and 13.NOTE: For impellers with replaceable rings – remove therings (4-004

Página 18 - Impeller rings can be added–

2514. Slide the deflector over the shaft end; then push the shaftend through the oil seal and slide stuffing box fully ontothe shaft. DO NOT COMPRESS

Página 19 - Photo 3 – Removing Stuff Box

3. Series DISASSEMBLYNOTICE: Numbers that appear in parenthesis ( ), such as(1-939-9), may be used to order replacement parts.3. Series HSC Pump – Pa

Página 20

27Remove coupler guard (see separate instructions on page29) and disconnect coupler.Remove external tubing (1-939-9) if supplied.2. Loosen but do not

Página 21 - Photo 10 – Rotating Element

13. Remove the other shaft sleeve and nut as described insteps 11 and 12.NOTE: For impellers with replaceable rings – remove therings (4-004-9) by cut

Página 22

15. Cool the bearing to room temperature and coat bothsides with two or three ounces of recommended grease.16. Coat the inside of the bearing housing

Página 23 - Photo 15 – Removing stuff Box

3SAFETYINSTRUCTIONSThis safety alert symbol will be used in this manual and on thepump safety instruction decals to draw attention to safety relatedin

Página 24

D. ORDERING PARTSThe pumps covered by this manual have been designed andbuilt with certain replaceable wearing parts. The recom-mended inventory of sp

Página 26 - Photo 23 – Pump with Packing

Xylem Inc. 8200 N. Austin Avenue Morton Grove, Illinois 60053 Phone: (847) 966-3700 Fax: (847) 965-8379www.xyleminc.com/brands/bellgossettG&L Pump

Página 27 - (Packing Installed)

PUMP LOCATIONLocate the pump so there is sufficient room for inspection, main-tenance and service. If the use of a hoist or tackle is needed,allow amp

Página 28

5INTRODUCTION1. Purpose of ManualThis manual is furnished to acquaint you with some of thepractical ways to install, operate, and maintain this pump.R

Página 29 - Photo 30 – Rotating Element

6Foundation bolts should be set in concrete as shown inIllustration 4. An optional 4-inch long tube around the bolts atthe top of the concrete will al

Página 30 - DEALER SERVICING

711. ANSI/OSHA COUPLER GUARDREMOVAL/INSTALLATIONNOTE: Do not spread the inner and outer guards more thannecessary for guard removal or installation. O

Página 31

8Method 1 – Straight Edge Alignment for Standard SleeveType Coupler with Black Rubber Insert (See Illustration 6A)Before aligning the coupler, make su