Página 1 - Base Mounted Centrifugal Pump

INSTRUCTION MANUAL AC2008BINSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER’S USE.Series HSC3Base Mounted Centrifugal PumpSeries HSC3Base Mounted Cent

Página 2 - BELL & GOSSETT  PUMP

10Suction piping should be short in length, as direct as possible,and never smaller in diameter than the pump suction opening.If the suction pipe is s

Página 3 - ROTATING COMPONENTS

11OPERATION1. Pre-start ChecksBefore initial start of the pump, make the followinginspections:a. Check alignment between pump and motor.b. Chec

Página 4 - CHILLER OR CONVER

12CHANGING ROTATIONSeries HSC3centrifugal pumps can be operated left hand orright hand when viewed from the pump end of the pump. Ifyou wish

Página 5 - Instructions

13TROUBLE SHOOTINGBetween regular maintenance inspections, be alert for signs ofmotor or pump trouble. Common symptoms are listed below. Correct any t

Página 6 - Illustration 3 – Foundation

14Not Enough PressureCAUSES CURES21. Mechanical defects. See items 14 and 15.22. Obstruction in liquid passages. Dismantle pump and inspect passages o

Página 7 - Pump Installation

15MAINTENANCE1. General MaintenanceOperating conditions vary so widely that to recommend oneschedule of preventative maintenance for all centrifuga

Página 8 - INCORRECT ALIGNMENT

SERVICE INSTRUCTIONSFOR AN HSC3PUMPTo Replace the Mechanical Seals and Bearingswithout removing Upper Half of the CasingNOTE: In order to replace the

Página 9 - (Piping Supports Not Shown)

6. Insert threaded rods into the tapped holes in the glandplate and install a fixture on the threaded rods to use apuller. (See Illustration 10 fo

Página 10

183. Lubricate and roll the O-ring into the groove in the glandplate.IMPORTANT: Steps 4 and 5 must be completed within10 to 12 minutes to assure prop

Página 11 - OPERATION

5. Tap the stuffing boxes with a soft-headed hammer tobreak the seal between the stuffing box and lower casinghalf, and lift the rotating element out

Página 12 - CHANGING ROTATION

BELL & GOSSETT  PUMPMODEL NO.SERIALNO.IDENT.NO.G.P.M.  FT. HP R.P.M.P.S.I.MAX.WORKPRESS.6 x 8 x

Página 13 - TROUBLE SHOOTING

20Reassembly of the Pump when it is required toremove the Rotating Element of the PumpNOTE: All bearings, O-rings, lip-seals, mechanical seals,gaskets

Página 14

2114. Lubricate and roll the O-rings into the groove in eachstuffing box.NOTE: At this point reassemble the rotating element bystarting on the outb

Página 15

Xylem Inc. 8200 N. Austin Avenue Morton Grove, Illinois 60053 Phone: (847) 966-3700 Fax: (847) 965-8379www.xyleminc.com/brands/bellgossettBell & G

Página 16 - Cross-Section

3SAFETYINSTRUCTIONSThis safety alert symbol will be used in this manual and on thepump safety instruction decals to draw attention to safety relatedin

Página 17 - 1.25"

4ADDITIONAL SAFETY REQUIREMENTS:ELECTRICAL SAFETY:THERMAL SAFETY:MECHANICAL SAFETY:WARNING: Electrical Shock HazardElectrical connections to be made b

Página 18

INTRODUCTION1. Purpose of ManualThis manual is furnished to acquaint you with some of thepractical ways to install, operate, and maintain this pump.Re

Página 19 - Photo 7 – Rotating element

6Foundation bolts should be set in concrete as shown inIllustration 3. An optional 4-inch long tube around the bolts atthe top of the concrete will al

Página 20

712. ANSI/OSHA COUPLER GUARDREMOVAL/INSTALLATIONNOTE: Do not spread the inner and outer guards more thannecessary for guard removal or installation

Página 21 - Photo 15 – Casing mainjoint

Method 1 – Straight Edge Alignment for Standard SleeveType Coupler with Black Rubber Insert (See Illustration 5A)Before aligning the coupler, make

Página 22 - DEALER SERVICING

913. DOWELINGDowel the pump and driving unit as follows:a. Drill holes through diagonally opposite feet and into thebase. Holes must be of a diamet